A SERVICE OF

logo

5. BASE SPECIFICATIONS PARAMETERS
II - 55
# Items Details Setting range (unit)
1222 aux06
(bit0)
Validity of tool
length
measurement
confirmation
message
0: Display no confirmation message when tool
compensation data is set.
1: Display a confirmation message when tool
compensation data is set.
0/1
aux06
(bit1)
Height axis
specification
When 1 is set in this parameter, the axis specified
by base specification parameter #1028 base_k is
measured and no other axes are measured if they
move.
0/1
aux06
(bit2)
Servo
waveform
display
Specify whether to enable the waveform display
function.
0: Disable the waveform display function.
1: Enable the waveform display function.
0/1
aux06
(bit3)
Enable/disable
setup parameter
lock
Specify whether to enable the setup parameter lock
function.
0: Disable
1: Enable
0/1
aux06
(bit4)
Minimum cut-in
amount
selection
Select the minimum cut-in amount command value
for the compound type thread cutting cycle (G76
command) when the minimum cut-in amount (Q)
does not exist in 1st block or 1st block is omitted.
0: The minimum cut-in amount (Q) is "0.".
1: The minimum cut-in amount (Q) is the last
command value.
0/1
aux06
(bit5)
Fixed cycle
for compound
lath command
format check
selection
Select the operation to be made if the 1st block of
the fixed cycle for compound lathe is omitted when
the conventional format is selected (#1265
ext01/bit0 "0").
0: Program error (P33) occurs.
1: Parameter setting value is used.
0/1
aux06
(bit7)
Zero point return
deceleration
check method
Set the deceleration check method used during
automatic reference point return.
0: In-position check
1: Commanded deceleration check
0/1