![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/a5/aa541565-2944-4e23-bef2-c708678fe848/aa541565-2944-4e23-bef2-c708678fe848-bga4.png)
5. BASE SPECIFICATIONS PARAMETERS
II - 77
(SETUP PARAM 1. 11/16)
# Items Details Setting range (unit)
1501 polyax
(For L
system
only)
Not used.
1502 G0Ipfg
G1 → G0
deceleration
check
0: Do not perform a deceleration check when the
move direction is changed from G1 to G0.
1: Perform a deceleration check when the move
direction is changed from G1 to G0.
0/1
1503 G1Ipfg
G1 → G1
deceleration
check
0: Do not perform a deceleration check when the
move direction is changed from G1 to G1.
1: Perform a deceleration check when the move
direction is changed from G1 to G1.
0/1
1505 ckref2 Second origin
return check
Specify the trigger for a check at the specified position
in manual second original return mode.
0: Completion of spindle orientation
1: Generation of second origin return interlock
signal
0/1
1506 F1_FM Not used.
1507 F1_K Not used.
1510 DOOR_H Shorten door
interlock II
axis stop time
Specify whether to shorten the time during which the
axis is stopped when the door is opened.
0: Use the conventional axis stop time.
1: Shorten the axis stop time.
Note: When the door interlock II signal is input via a
ladder, the conventional axis stop time is used.
0/1
1511 DOORPm Signal input
device 1 for
door interlock
II: for each
system
Specify the fixed device number (X??) for door
interlock II signal input for each system.
A device number from X01 to XFF can be specified.
Device number 000 is invalid.
Specify device number 100 when using no fixed
device number for door interlock II signal input.
Related parameter: #1154 pdoor (Door interlock II for
each system)
000 to 100
(hexadecimal)
1512 DOORPs Signal input
device 2 for
door interlock
II: for each
system
Specify the fixed device number (X??) for door
interlock II signal input for each system.
(Specify the same value as that of #1155.)
Related parameter: #1154 pdoor (Door interlock II for
each system)
000 to 100