![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/a5/aa541565-2944-4e23-bef2-c708678fe848/aa541565-2944-4e23-bef2-c708678fe848-bg18e.png)
13. AUXILIARY AXIS PARAMETER
II - 311
No. Name Details Setting range
Default
value
101
(PR)
Cont1 Control
parameter 1
This is a HEX setting parameter. Set bits without a description to their default
values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
Default
value
00000010000 0 0 000
bit Meaning when "0" is set Meaning when "1" is set
0
1
High-speed zero point return
after establishment of zero point.
Dog-type return for each zero
point return operation.
2
3
4
5
6
7
8
Reference point return direction
(+)
Reference point return direction
(-)
9
Rotation direction determined by
operation control signal (DIR)
Rotation direction in the shortcut
direction
A
Machine basic position becomes
the origin point
Electrical zero point becomes the
origin point
B
C
D
Coordinate zero point creation
valid
Zero point established at power
supply ON position
E
Rotation direction in operation
control signal (DIR) or in the
shortcut direction
Rotation direction in the random
position command sign direction
F
Stopper direction is positioning
direction
Stopper direction is in the sign
direction of the stopper amount