Furuno FS-5070 Cell Phone User Manual


 
6. MENU OPERATION
6-20
6.13 Setting Scan Frequencies
The Scan freq menu determines which DSC routine and distress frequencies to scan.
Follow the instructions below to select/deselect DSC routine and distress frequencies to
scan.
1. Press the #/SETUP key.
2. Rotate the ENTER knob to choose USR SETUP, and push the ENTER knob.
3. Rotate the ENTER knob to choose SCAN FREQ, and then push the ENTER knob to
display the Scan freq setup menu.
DISTRESS
2M :
FIXED
4M :
ON
6M : ON
8M :
FIXED
12M : ON
16M : OFF
**
Scan freq setup
*
ROUTINE
F1 : 2M-INTL
F2 : 4M-INTL
F3 : 6M-INTL
F4 : 8M-INTL
F5 : 12M-INTL
F6 : 16M-INTL
Distress and safety frequencies
1. Rotate the ENTER knob clockwise to shift the cursor to the DISTRESS column.
2. Rotate the ENTER knob to choose the frequency band and then push the ENTER knob.
For example, choose 4 MHz.
ROUTINE
F1 : 2M-INTL
F2 : 2M-INTL
F3 : 4M-INTL
F4 : 8M-INTL
F5 : 12M-INTL
F6 : 16M-INTL
DISTRESS
2M :
FIXED
4M : ON
6M : ON
8M :
FIXED
12M : ON
16M : OFF
**
Scan freq setup
*
OFF
ON
3. Rotate the ENTER knob to choose ON or OFF as appropriate and then push the
ENTER knob.
4. Press the CANCEL key three times to return to the radiotelephone screen.
Note: Regulations require that 2 MHz and 8 MHz and one more DSC distress frequency be
watched continuously. 2 MHz and 8 MHz cannot be turned off. Maximum three bands
may be turned off.