A SERVICE OF

logo

3. BASIC OPERATIONS
Where AT100 series is connected:
1) Turning the power on
To turn the power on, turn on the main power switch on the rear panel.
If this is the first time since setting up the KA counter, the display will blink.
(This indicates that the displayed value is of no use.)
By pressing the Cancel key, the counter is ready to display a normal count value.
By referring to “3.2.3 Zero-set”, “3.2.4 Preset”, and “3.2.5 Saving and recalling a
datum point using the scale reference point”, set a machining datum point.
2) Turning the power off
Use the display ON/FF switch on the front panel to turn the power off while remaining
the main power switch on the rear panel on.
By pressing the display ON/OFF switch, the display can be off.
3) Turning the power on again
Press the display ON/OFF switch on the front panel.
The display will be on.
NOTE
• If there happened an abnormality in the power line, such as a power failure, the next
time the power is turned on using the display ON/OFF switch, the display will blink as
described in 1) above. If this happens, set the reference point for machining again.
When the display is blinked even if parameter No. 15, described in Chapter 4, has been
set to “Save display”, this indicates that the displayed value is of no use. If this happens,
set the reference point for machining again.
No. 99MBE032A
3-3