Where AT700 series is connected:
1) Turning the power on
To turn the power on, turn on the main power switch on the rear panel.
At this time, the display indicates the distance from the scale reference point.
By referring to “3.2.3 Zero-set”, “3.2.4 Preset”, and “3.2.6 Setting the machine origin
with the AT700 series”, set a machining datum point.
2) Turning the power off
Use the display ON/FF switch on the front panel to turn the power off while remaining
the main power switch on the rear panel on.
By pressing the display ON/OFF switch, the display can be off.
3) Turning the power on again
Press the display ON/OFF switch on the front panel.
The display will be on.
3.2.2 Counting and displaying
This section is for the user who is using the KA counter with a minimum resolution of
0.0005 or 0.0001mm (0.5 or 0.1µm).
The user who is using it with a minimum resolution of 0.005 or 0.001mm (5 or 1µm) may
skip this section.
• In order to expand the display range of the KA counter, the counting range in the +
count direction and the - count direction are different.
The counting range when the KA counter is used with the minimum resolution of
0.0005 or 0.0001mm (0.5 or 0.1µm) is as follows:
+9999.9999 to -999.999 (approximately +10m to -1m)
No. 99MBE032A
3-4