4.2.2 Parameters common to all axes
Parameter
No.
Parameter Function Setup Data Initial Value
0 • Internal memory initialization Refer to
section 4.3.5
10 • Smoothing
Reduces the display flickering when the
scale unit is installed on a machine that
creates significant vibrations.
0: OFF
1: ON
0 (OFF)
12 • Linear error correction selection
Select either use linear error correction function
or not.
0: Normal
display
1: Linear error
correction
function is
used.
0 (Normal
display)
13 • Specifying the number of axes
Set to 0 when the counter is used as a 1-axis
counter. This setup is applied only to a 2-axis
counter.
0: 1-axis
1: 2-axis
1 (2-axis)
(only 2-axis
counter is
valid)
18 • Specifying the operable model
Set to 1 when the counter is used as a lathe
counter.
0: Standard
1: Lathe
0 (Standard)
42
Note 1)
• Switching the inch calculation accuracy 0: Standard
1: High-
precision
0 (Standard)
43 • Addition mode setting (This parameter function
is available exclusively with 3-axis counter.)
The sum of the scale outputs of Y-axis and
Z-axis is displayed.
0: Normal
display
1: Addition
mode
setting
84 • RS232C baud rate setting
Sets the baud rate if the optional RS232C code
out unit has been connected to communicate
with external devices.
0: 300bps
1: 600bps
2: 1200bps
3: 2400bps
4: 4800bps
5: 9600bps
6: 19200bps
4 (4800bps)
85 • RS232C parity setting
Sets the parity when the optional RS232C code
out unit has been connected to communicate
with external devices.
0: None
1: Even
2: ODD
1 (Even)
No. 99MBE032A