Parameter
No.
Parameter Function Setup Data Initial Value
51
• Scale reference point detecting direction setting
(Available only when the AT100 series is
connected.)
Sets the scale reference point detecting
direction.
0: - count
direction
1: + count
direction
2: Both
direction
1 (+ count
direction)
91 • Resolution setting
Switches the resolution among those described
on the right.
0: 1µm
1: 2µm
2: 5µm
3: 10µm
2 (5µm)
Note 1) • About Parameter 15 (Storing the display value) and coordinate restoration manner for
each scale type
For each scale to be connected (AT100 series or AT700 series) the condition of
coordinate restoration after the power is reset differs. The following table lists the counter
display values when the power is once turned off then on again.
Setup Data AT700 Series AT100 Series
Coordinate 0: Perfect restoration *
1
Coordinate 0: 0.000
0
Coordinate 1 to 9: 0.000 Coordinate 1 to 9: 0.000
Coordinate 0: Perfect restoration *
1
Coordinate 0:
Display value before the power was
turned off *
2
1
Coordinate 1 to 9:
Perfect restoration *
1
Coordinate 1 to 9:
Display value before the power was
turned off *
2
*1: Perfect restoration
Even when the table was fed while the power was off, the correct value will be
displayed after the power is turned on again.
*2: Display value before the power was turned off
The display value when the power was last turned off is retained. If the table was fed
while the power was off, the correct value will not be displayed after the power is
turned on again, and the display will flash. This shows the reliability of the display
value is poor.
No. 99MBE032A