Panasonic KX-TGP500 Cell Phone User Manual


 
Configuration File Reference CFG_MASTER_FILE_PATH (Page 146)
Cyclic Auto Resync
Description Selects whether the unit periodically checks for updates of configuration
files.
Value Range
Yes
No
Default Value No
Configuration File Reference CFG_CYCLIC (Page 148)
Resync Interval
Description Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
Value Range 1–40320
Default Value 10080
Configuration File Reference CFG_CYCLIC_INTVL (Page 149)
Header Value for Resync Event
Description Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range Max. 15 characters
Note
If the value for this setting is any value other than an empty
string (typically "check-sync" or "resync" is set), the unit will
access the configuration files on the provisioning server when
the SIP server sends an event to notify the unit.
If the value for this setting is an empty string, the unit will not
access the configuration files on the provisioning server even if
the unit receives a synchronization notification of an event.
Default Value check-sync
Configuration File Reference CFG_RESYNC_FROM_SIP (Page 150)
3.8.4 Reset to Defaults
This screen allows you to reset the settings made through the Web user interface to their default values by
clicking [Reset Web Settings]. After you click this button, a dialog box is displayed, asking whether you want
to reset the settings. Click OK to reset, or Cancel not to. For details about the reset, see 1.2.1.2 Resetting
the Settings Made through the Web User Interface (Reset Web Settings).
122 Administrator Guide Document Version 2010.03.15
3.8.4 Reset to Defaults