Web User Interface Reference Tone Timings (Page 113)
RINGING_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range 0, 200–1000 (0: No tone)
Default Value 440,480
Web User Interface Reference Tone Frequencies (Page 113)
RINGING_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of ringback tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 2000,4000,2000,4000
Web User Interface Reference Tone Timings (Page 114)
STT_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of stutter dial tones to
notify that a voice mail is waiting, using 2 whole numbers separated by
a comma.
Value Range 0, 200–1000 (0: No tone)
Default Value 350,440
Web User Interface Reference Tone Frequencies (Page 114)
STT_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of stutter dial tones to notify that
a voice mail is waiting, using 22 whole numbers (on 1, off 1, on 2, off 2,
…, on 11, off 11) separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 100,100,100,100,100,100,100,100,100,100,100,100,100,
100,100,100,100,100,100,100,0,0
164 Administrator Guide Document Version 2010.03.15
4.5.2 Tone Settings