SYSLOG_ADDR
Value Format String
Description Specifies the IP address or FQDN of the syslog server.
Value Range Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value Empty string
SYSLOG_PORT
Value Format Integer
Description Specifies the port number of the syslog server.
Value Range 1–65535
Default Value 514
SYSLOG_RTPSMLY_INTVL_[1–8]
Parameter Name Example SYSLOG_RTPSMLY_INTVL_1, SYSLOG_RTPSMLY_INTVL_2, …,
SYSLOG_RTPSMLY_INTVL_8
Value Format Integer
Description Specifies the interval, in seconds, to send summarized information of
RTP packets to the syslog server.
Value Range 0, 5–65535 (0: No information sent)
Default Value 20
4.3.4 Firmware Update Settings
FIRM_UPGRADE_ENABLE
Value Format Boolean
Description Specifies whether to perform firmware updates when the unit detects a
newer version of firmware.
Note
• Changing this setting may require restarting the unit.
• Local firmware updates from the Web user interface (® see
3.8.2 Local Firmware Update) can be performed regardless
of this setting.
Value Range
• Y (Enable firmware updates)
• N (Disable firmware updates)
Default Value
Y
Document Version 2010.03.15 Administrator Guide 141
4.3.4 Firmware Update Settings