Value Range Max. 255 characters
Note
• The format must be RFC 1738 compliant, as follows:
"<schema>://<user>:<password>@<host>:<port>/<url-path>"
– "<user>" must be less than 64 characters.
– "<password>" must be less than 64 characters.
– "<user>:<password>@" may be empty.
– The total of "<schema>://" and "<host>:<port>/<url-path>"
must be less than 128 characters.
– ":<port>" can be omitted if you do not need to specify the
port number.
• If "{mac}" is included in this URL, it will be replaced with the
unit’s MAC address in lower-case.
• If "{MAC}" is included in this URL, it will be replaced with the
unit’s MAC address in upper-case.
• If "{MODEL}" is included in this URL, it will be replaced with the
unit’s model name.
• If "{fwver}" is included in this URL, it will be replaced with the
unit’s firmware version.
• If this URL ends with "/" (slash), "sip.cfg" is automatically added
at the end of the URL.
For example, CFG_MASTER_FILE_PATH="http://host/
dir/" becomes CFG_MASTER_FILE_PATH="http://
host/dir/sip.cfg".
Default Value Empty string
Note
• The URL specified by your phone system dealer may be preset
in the unit.
Web User Interface Reference Master File URL (Page 121)
CFG_FILE_KEY1
Value Format String
Description Specifies the encryption key (password) used to decrypt configuration
files.
Note
• If the extension of the configuration file is ".e1c", the
configuration file will be decrypted using this key.
Value Range 32-byte characters
Note
• If an empty string is set for this parameter, decryption with this
value is disabled.
Default Value A unique value is preset to each unit.
Document Version 2010.03.15 Administrator Guide 147
4.3.5 Provisioning Settings