Dolphin Peripherals 6100 Cell Phone Accessories User Manual


 
5 - 4
SuffixID Specifies the symbology identifier sent
after the decoded/received data.
0
0=No symbology identifier is sent.
1=The Code ID is sent.
2=The AIM ID is sent.
3=The SymModifier is sent.
SoundConnect Enables and disables
The sound that ScanWedge makes
when starting up, shutting down, or
restarting.
The audio notification when an IrDA
session is established and closed and
the serial port is opened and closed.
1
0=Disabled
1=Enabled
Audio notifications for errors can’t
be disabled.
MessageConnect
This key applies only to
the IrDA and serial ports.
Enable and disables a notification
message when an IrDA session is
established and closed and the serial port
is opened and closed.
0
0=Disabled
1=Enabled
Accept EZConfig
This key applies only to
the decoder.
Enables and disables ScanWedge’s
compatibility with EZConfig Client when
decoding bar codes.
1
0=Disabled; ScanWedge processes
EZConfig barcodes as it would
any other barcode.
1=Enabled; ScanWedge recognizes
EZConfig barcodes and passes
them on to the EZConfig Client
for further processing.
Settings Section
The Settings section determines how ScanWedge interprets data from the decoder, serial port, and IrDA
interface.
0 = Disable 1 = Enable
Settings Section
Key
Description
Default
Value
Available Values