A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
120 Application Enhancement Solutions Messages Manual
BMC48032I CONTROL CARD DID NOT CONTAIN KEYWORDS AND WAS
BYPASSED
Explanation: A control statement found in the SYSIN data set did not contain
any keywords.
System Action: Processing continues. The control statement is bypassed. The final
return code for the utility execution is 4 unless other utility requests result in a higher
return code.
User Response: Verify the control statement was not intended to be a comment (*)
in position 1 or was incorrectly specified. The SYSPRINT data set contains a listing
of the control statements processed from the SYSIN data set.
BMC48033I ERROR FOUND IN FOLLOWING CONTROL STATEMENT
Explanation: The request processor found an error in a control statement.
System Action: The utility execution terminates with a U4033 abend.
User Response: Correct the control statement in error. The control statement is
listed following message BMC48033I. Then resubmit the job.
BMC48034I ERROR PARSING OUTPUT DDNAME
Explanation: The output ddname operand contained in the operands for the
request is invalid.
System Action: Processing continues. Message BMC48033I is issued.
User Response: Correct the control statement in error. The output ddname must be
from one to eight characters in length.
BMC48035I ERROR PARSING 2ND INPUT DDNAME
Explanation: The second input ddname operand contained in the operands for
the request is invalid.
System Action: Processing continues. Message BMC48033I is issued.
User Response: Correct the control statement in error. The second input ddname
must be from one to eight characters in length. Then resubmit the job.
BMC48036I PSB= OR UOW= OR BBO= OR TRAN= OPERAND PARSING ERROR
Explanation: The operand associated with one of the minor keywords is invalid.
System Action: Processing continues. Message BMC48033I is issued.
User Response: Correct the operand associated with the minor keyword. The PSB,
BBO, or TRAN name must be one to eight characters in length. The UOW operand
must be eight characters in length.