A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
Abend Codes 11
U747 The BATCH CONTROL FACILITY (BCF) Backout Assist feature encountered an
error that can make the results of the IMS Batch Backout utility execution
unpredictable. The abend is issued to prevent database damage.
System Action: The job step or the batch backout operation terminates abnormally.
User Response: If the reason for the abend cannot be determined and corrected,
execute the IMS Batch Backout utility without the Backout Assist feature active. The
Backout Assist feature can be deactivated by including a DD statement
(BCFBAIGN, DD DUMMY) in the JCL for the step.
U778 APPLICATION RESTART CONTROL (AR/CTL) detected that the application
program issued a
ROLL call.
System Action: AR/CTL issues message BMC74297I and terminates abnormally.
User Response: Contact the application programmer to determine why the
application issued the
ROLL call and determine the action to take.
U1550 During BATCH CONTROL FACILITY (BCF) restart processing, the previous job
step abended, and the job step member was marked active. This user abend occurs
when the last BCF task that was active fails to complete its processing. Completion
of job step processing is indicated by an ENDED or ENDED+ABENDED status
message displayed beside the execution control record.
System Action: Processing terminates.
User Response: Use the Display Active Job Step Member panel to mark the
execution control record as abnormally terminated.
As a result of this user abend, any steps coded as
COND=ONLY for batch backout are
bypassed if BCF is active for the job step.
U1551 An error occurred during Application Enhancement Solutions (AES) initialization.
System Action: Processing terminates.
User Response: Check the messages issued during the job step for details about the
cause of the error and the action to take.
U1552 BATCH CONTROL FACILITY (BCF) restart processing has completed all
recovery steps necessary for application restart. The execution control record
indicates that deferred application restart processing has been requested.
System Action: Processing terminates.
User Response: This abend is issued to prevent execution of any additional steps
contained in the job and does not indicate an error condition.
As a result of this user abend, any steps coded as
COND=ONLY for batch backout are
bypassed if BCF is active for the job step.