BMC Software, Inc., Confidential and Proprietary Information
152 Application Enhancement Solutions Messages Manual
BMC74055E NO CHKP CALL WAS ISSUED DURING EXECUTION OF JOB jobname,
STEP stepname, PSB or ASB name, AND PGM pgmname
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application did not issue a
CHKP call during the execution of the job step
identified by the specified job name, step name, program specification block (PSB)
name or application specification block (ASB) name, and application program name.
System Action: If the current value of the Check
CHKP option is ABEND,
AR/CTL abnormally terminates the step with abend U1771 and reason code
X’00074055’; otherwise, processing continues.
User Response: If
necessary, change the application to issue at least one CHKP call.
BMC74056E A DL/I type CALL WAS ISSUED BEFORE A DL/I CHKP CALL WAS
ISSUED
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application did not issue a
CHKP call before issuing the given type of database
call during the execution of the job step.
System Action: If the current value of the Check Updates option is ABEND,
AR/CTL abnormally terminates the step with abend U1771 and reason code
X’00074056’; otherwise, processing continues.
User Response: If
necessary, change the application to issue the CHKP call before
issuing any database update calls.
BMC74057E VERSION v RELEASE r OF IMS IS NOT SUPPORTED
Explanation: APPLICATION RESTART CONTROL (AR/CTL) does not
support the given version (v) and release (r) of IMS.
System Action: AR/CTL abnormally terminates the task with abend U1771 and
reason code X’00074057’.
User Response: Contact your BMC Software sales representative to obtain a
release of AR/CTL that supports the specified version and release of IMS.
BMC74058E VERSION v RELEASE r OF IMS MODULE module HOOK ADDRESS
CANNOT BE DETERMINED
Explanation: APPLICATION RESTART CONTROL (AR/CTL) cannot plant
the required hook in the given version (v) and release (r) of the given IMS module
because the address in this module cannot be determined.
System Action: AR/CTL abnormally terminates the task with abend U1771 and
reason code X’00074058’.
User Response: Save the SYSUDUMP data set and the JES message log for this
job, and contact BMC Software Product Support.