BMC Software, Inc., Confidential and Proprietary Information
84 Application Enhancement Solutions Messages Manual
BMC44220I READ REQUEST FAILED, DYNAMIC LOG WAS SUSPENDED
Explanation: The job step was using a dynamic log to provide read services for
the IMS dynamic backout process. A
READ request could not be satisfied because
the block was not contained in the dynamic log and the use of the dynamic log was
suspended when it became full.
System Action: The IMS dynamic backout process fails because of the read error
on the dynamic log. The execution controller may attempt database backout by using
the IMS Batch Backout utility.
User Response: Increase the size of the dynamic log, or issue the DL/I application
checkpoints more frequently. Increasing the size of the dynamic log is usually
preferable.
The number of blocks specified for the dynamic log must be large enough to contain
all blocks written to the IMS log data set between checkpoints. The Application
Checkpoint Detail report (provided when the BCFSTATS DD statement is present)
can help determine the number of blocks necessary to prevent suspension of the
dynamic log.
BMC44222E RGX WRITE ERROR; REC TYPE = type
Explanation: An attempt to write to the REGISET failed when BATCH
CONTROL FACILITY (BCF) attempted to write job information to the REGISET.
The type value indicates the type of record being written to the REGISET. The
following values are possible:
3 execution control record
4 primary log volume record
5 secondary log volume record
7 statistics record
System Action: The actions taken by BCF depend both on the function that detects
the error and on how the execution options are specified.
User Response: Correct the problem that caused the error and resubmit the job. For
a discussion of the actions taken, see the section on the REGISET in the Application
Enhancement Solutions Installation Guide. Have the job log data set available if you
need to contact BMC Software Product Support for assistance.