A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
BMC74000BMC74099 151
BMC74047E CHKP CALL RETURNED STATUS CODE sc IN type PCB
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application checkpoint call returned status code sc in the given type of program
communication block (PCB). The restart data set shows the checkpoint as
incomplete. The accompanying message BMC74048E displays the PCB type and the
PCB contents.
System Action: AR/CTL also issues message BMC74048E. Processing continues.
User Response: Review the cause the of the error, and take corrective action in the
application program or database.
BMC74048E type PCB contents
Explanation: This message, which accompanies message BMC74047E, displays
the program communication block (PCB) type and the PCB contents.
System Action: See message BMC74047E.
User Response: See message BMC74047E.
BMC74049E STEP WILL ABEND BECAUSE USER EXIT RETURNED CODE XC
Explanation: The return code from the XRST/CHKP user exit was XC, which
requests that APPLICATION RESTART CONTROL (AR/CTL) abnormally
terminate the job step.
System Action: AR/CTL abnormally terminates the task with abend U1771 and
reason code X00074049.
User Response: This message is for your information only. No action is necessary.
BMC74054E NO XRST CALL WAS ISSUED DURING EXECUTION OF JOB jobname,
STEP stepname, PSB or ASB name, AND PGM pgmname
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the application did not issue an
XRST call during the execution of the job step
identified by the given job name, step name, program specification block (PSB)
name or application specification block (ASB) name, and application program name.
System Action: If the current value of the Check
XRST option is ABEND,
AR/CTL abnormally terminates the step with abend U1771 and reason code
X00074054; otherwise, processing continues.
User Response: If
necessary, change the application to issue the XRST call.