BMC Software, Inc., Confidential and Proprietary Information
BMC150000–BMC150099 331
BMC150053E SEQUENTIAL INTERCEPT IS NOT ALLOWED WHEN USING VSAM FILE
SHARING ONLY
Explanation: Application programs that use the VSAM File Sharing Only option
of APPLICATION RESTART CONTROL (AR/CTL) may not use any sequential
interception file characteristics blocks (FCBs). They may use only FCBs defined for
VSAM access files.
System Action: AR/CTL abnormally terminates the task with abend U1773.
User Response: Remove the sequential interception FCBs from the FCB library.
BMC150054E FCB ACCESS LEVEL 0 AND 1 ARE NOT ALLOWED WHEN USING VSAM
FILE SHARING ONLY
Explanation: Application programs that use the VSAM File Sharing Only option
of APPLICATION RESTART CONTROL (AR/CTL) must use VSAM file
characteristics blocks (FCBs) that specify access level 2 or 3.
System Action: AR/CTL abnormally terminates the task with abend U1773.
User Response: Use only FCB access levels 2 or 3 for all VSAM data sets.
BMC150055W REATTACH OPTION CHANGED TO NO BECAUSE PROGRAM
ABENDED BEFORE XRST
Explanation: The application program abended before APPLICATION
RESTART CONTROL (AR/CTL) processed a restart request. The program is not
restartable if restart request processing is not complete before the abend occurs.
Therefore, reattach cannot be performed. The value of the reattach option is changed
from YES to NO.
System Action: Abnormal termination of the task continues; AR/CTL does not
perform application reattach.
User Response: Resolve the problem, and restart the application program from the
beginning.
BMC150056E BOTH THE DDN AND COUNT FOR THE AUTOMATIC SYNCPOINT
TRIGGER FILE MUST BE SPECIFIED
Explanation: To enable APPLICATION RESTART CONTROL (AR/CTL)
automatic syncpoint processing, you must specify the automatic syncpoint trigger
file ddname and the count of I/O requests.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues in batch mode.
User Response: Ensure that the ddname and the count are specified for the
automatic syncpoint trigger file.