BMC Software, Inc., Confidential and Proprietary Information
376 Application Enhancement Solutions Messages Manual
BMC150209E LOAD FAILED FOR MODULE modulename, RC=returncode
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) for Open
Systems application program interface (API) could not locate or load the indicated
module from the STEPLIB library concatenation. During initialization, the API
preloads all required interface modules from the AR/CTL load library.
System Action: Preloading of the remaining modules continues. However,
processing is later terminated with message BMC150206E and abend U1786.
User Response: Make sure that the BMC Consolidate Subsystem (BCSS) is active
and that you are connected to the correct BCSS. Make sure that the environment
registration record has the correct AR/CTL library name specified. If the problem
cannot be resolved, contact BMC Software Product Support.
BMC150210E RECORD LENGTH GREATER THAN MAX SPECIFIED, REREAD
SUPPORT WILL NOT BE AVAILABLE
Explanation: During APPLICATION RESTART CONTROL (AR/CTL)
processing for a program that uses the AR/CTL for Open Systems application
program interface (API), the length of a variable-length record that was read is
greater than the maximum length specified.
System Action: Processing continues. Any REREAD request for this file will fail.
User Response: Determine why the record length is greater than the maximum. If
the program does not issue any REREAD requests, you can ignore this message.
BMC150211E AN UNRECOVERABLE ERROR DETECTED IN THE AR/CTL FOR OPEN
SYSTEMS API
Explanation: An unrecoverable error occurred during a READ operation. Either
the address of the file characteristics block (FCB) in the application request block
(ARB) is missing, or the length of the record that was read is zero.
System Action: Processing is terminated with abend U1786.
User Response: Check for other error messages issued before this one. Make sure