BMC Software, Inc., Confidential and Proprietary Information
BMC155000–BMC155099 473
BMC155062W ENABLE, BLDL FAILED MODULE (<module>) R15(<contents>)
R0(<contents>).
Explanation: The ENABLE command was not processed because a BLDL
request for the indicated required module failed. The message displays the contents
of register 15 and register 0.
System Action: Restart Advisor processing continues.
BMC155063W ENABLE, LOAD FAILED MODULE (<module>) R15(<contents>)
R0(<contents>).
Explanation: The ENABLE command was not processed because a load request
for the indicated required module failed. The message displays the contents of
register 15 and register 0.
System Action: Restart Advisor Processing continues.
BMC155064W ENABLE, ATTACH FAILED MODULE (<module>) R15(<contents>)
R0(<contents>).
Explanation: The ENABLE command was not processed because an attach
request for the indicated required module failed. The message displays the contents
of register 15 and register 0.
System Action: Restart Advisor Processing continues.
BMC155065W ENABLE, RMG PAS CONNECTION ALREADY ENABLED.
Explanation: The ENABLE command was not processed. The Restart Advisor
product address space (PAS) could not be enabled because it was already enabled.
System Action: Restart Advisor Processing continues.
BMC155066W ENABLE, RMG ENABLE PAS PARAMETER INVALID.
Explanation: The ENABLE command was not processed. The Restart Advisor
product address space (PAS) could not be enabled because no SSID parameter was
supplied.
System Action: Restart Advisor Processing continues.
BMC155075I <text>
Explanation: This general purpose message is used to display the response to
Restart Advisor component commands.
System Action: Restart Advisor Processing continues.