A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
294 Application Enhancement Solutions Messages Manual
BMC93066E SHOWCAT ERROR, CANNOT DETERMINE FILE TYPE. FILE=file id
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected an
error during
SHOWCAT processing and cannot determine the file type of the given
data set (file id).
System Action: The system action depends on the access level (
ACCLVL)
specified. The following values are valid for the access level:
2 continue with local VSAM access
3 abend
User Response: Check the catalog status. If it seems to be valid, call BMC
Software Product Support for assistance.
BMC93067E ERROR DURING MRO LOGON, PLEASE VERIFY CICS SVC NUMBER
Explanation: An error occurred during MRO logon. The problem might have
been caused by an invalid CICS SVC number.
System Action: APPLICATION RESTART CONTROL (AR/CTL) terminates the
job abnormally; the abend code depends on the SVC value.
User Response: Verify that the correct CICS SVC number is specified with the
CICS SVC Number processing option.
BMC93068I OLD AR/CTL FOR VSAM FILE TABLE DELETED
Explanation: The last remote VSAM access file table built for APPLICATION
RESTART CONTROL (AR/CTL) for VSAM has been deleted.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.
BMC93069I FCT SCAN COMPLETED, EXIT {INITIALIZED | ALREADY ACTIVE}
Explanation: APPLICATION RESTART CONTROL (AR/CTL) for VSAM has
completed a file control table (FCT) scan and has built the remote VSAM access file
table, and the global user exit has been initialized or was already active.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.