194 Application Enhancement Solutions Messages Manual
BMC74218E CONNECTION WITH DB2 SUBSYSTEM ssid RETURNED CODE rc AND
REASON CODE reason.
Explanation: APPLICATION RESTART CONTROL (AR/CTL) attempted
connection with the given DB2* subsystem (ssid). The attempt was not successful,
and AR/CTL received return code rc and reason code reason. For an explanation of
the return code and reason code, refer to the IBM DATABASE 2 Messages and Codes
manual.
System Action: AR/CTL abnormally terminates the task with abend U1776 and
reason code X00074218.
User Response: Review the JES message log and the data set containing
unsolicited status messages for the DB2 Call Attach Facility (found under ddname
DDOTV02). Take corrective action as indicated by the messages.
BMC74219E OPEN OF DB2 SUBSYSTEM ssid PLAN plan RETURNED CODE rc AND
REASON CODE reason.
Explanation: APPLICATION RESTART CONTROL (AR/CTL) attempted to
open the plan in the DB2 subsystem (ssid). The attempt was not successful, and
AR/CTL received return code rc and reason code reason. For an explanation of the
return code and the reason code, refer to the IBM DATABASE 2 Messages and Codes
manual.
You may receive this message when you use the Automatic Checkpoints and Trigger
Cursor Name processing options to take checkpoints based on fetch counts of a
cursor. This message is generated if the AR/CTL plan, ARCTLP$2 (install default),
has not been found on the DB2 system. You must run the install job $Q06BDGT on
every system where AR/CTL will run and must use the same plan name in every
DB2 system.
System Action: AR/CTL abnormally terminates the task with abend U1785 and
reason code X00074219.
User Response: Review the JES message log and the data set containing
unsolicited status messages for the DB2 Call Attach Facility (found under ddname
DDOTV02). Take corrective action as indicated by the messages.