BMC Software, Inc., Confidential and Proprietary Information
146 Application Enhancement Solutions Messages Manual
BMC74030E RESTART CONTROL RECORD record CONTAINS INVALID HEADER
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected
invalid header information in the given restart control record.
System Action: AR/CTL abnormally terminates the task with abend U1771 and
reason code X’00074030’.
User Response: Perform the restart using the IMS system log data set (SLDS), if
possible. Save the SYSUDUMP data set and JES message log for this job, and
contact BMC Software Product Support.
BMC74031E CONFLICT EXISTS BETWEEN RESTART CONTROL RECORD AND
RESTART DATA SET: option name
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected a
conflict in the specified information between the restart control record in the
REGISET and the restart data set. This message displays the name of the option that
is in conflict. Message BMC74032E displays the conflicting option setting from the
restart control record. Message BMC74033E displays the conflicting option setting
from the restart data set.
System Action: AR/CTL also issues messages BMC74032E and BMC74033E;
then it abnormally terminates the task with abend U1771 and reason code
X’00074033’.
User Response: If AR/CTL processed this job step as a non-unique job step,
provide the correct restart data set with the ARCXRST DD statement. If AR/CTL
processed this job step as unique, save the SYSUDUMP data set and JES message
log and contact BMC Software Product Support. Perform the restart using the IMS
system log data set (SLDS), if possible. If not, perform the procedure for handling a
damaged or destroyed restart data set as described in the APPLICATION RESTART
CONTROL User Guide.
BMC74032E CONFLICTING DATA FROM THE RESTART CONTROL RECORD: option
setting
Explanation: This message, which accompanies message BMC74031E, displays
the conflicting option setting from the restart control record.
System Action: See message BMC74031E.
User Response: See message BMC74031E.
BMC74033E CONFLICTING DATA FROM THE RESTART DATA SET: data
Explanation: This message, which accompanies message BMC74031E, displays
the conflicting option setting from the restart data set.
System Action: See message BMC74031E.
User Response: See message BMC74031E.