BMC Software, Inc., Confidential and Proprietary Information
BMC89000–BMC89099 267
BMC89063E THIS PASSWORD REQUIRES “NEWCPUID” AND “OLDCPUID”
KEYWORDS.
Explanation: The Replace password being processed requires specification of
the NEWCPUID and OLDCPUID keywords, but neither was specified.
System Action: The password is not processed.
User Response: Specify the NEWCPUID and OLDCPUID keywords on the input
control statement.
BMC89064W ERRORS CAUSED TERMINATION. SOME OR ALL REQUESTS DID NOT
COMPLETE SUCCESSFULLY.
Explanation: The input data contains one or more errors.
System Action: Processing terminates.
User Response: Examine the input control statements for errors. If you cannot
locate the errors, contact BMC Software Product Support for assistance.
BMC89065I ALL REQUESTS COMPLETED SUCCESSFULLY.
Explanation: All requested functions have been processed.
System Action: The product authorization table is updated.
User Response: None. Information only.
BMC89069E PERMANENT PRODUCT AUTHORIZATION TABLE’S GRACE PERIOD IS
INVALID. PLEASE CONTACT BMC PRODUCT SUPPORT.
Explanation: An error occurred which has invalidated the grace period in the
table. The table must be rebuilt.
System Action: All functions are suppressed.
User Response: Call BMC Software Product Support for assistance.
BMC89070E ISPF V3 REQUIRED. USE BATCH UPDATE pgm INSTEAD.
Explanation: ISPF Version 3 (or higher) is required to run the online customer
interface.
System Action: The online customer interface will terminate.
User Response: Use the batch update program or contact BMC Software Product
Support to obtain ISPF panels that are compatible with your version of ISPF.