BMC152100BMC152199 413
BMC152112W VSAM LOGGING COMPONENT IS NOT LICENSED FOR CPU ID <cpuid>.
<subsysid>
Explanation: The CPU ID number indicated in the message is not licensed for
APPLICATION RESTART CONTROL (AR/CTL) for VSAM. CPU IDs are
assigned to specific machines and are not valid if you change to a different machine.
System Action: AR/CTL for VSAM remains unavailable until a licensed CPU ID
is supplied.
User Response: Enter a valid CPU ID for AR/CTL for VSAM. If the CPU ID
shown is incorrect, contact BMC Software Contracts Administration.
BMC152113S Module <module> not available, Searched ARCLIB, STEPLIB, and
LNKLST. <subsysid>
Explanation: The Application Enhancement Solutions (AES) VSAM component
could not find the specified module in the ARCLIB, STEPLIB, or LNKLST
concatenation.
System Action: Initialization fails.
User Response: Add the library for the specified module to the ARCLIB,
STEPLIB, or LNKLST concatenation for the BMC Software Consolidated
Subsystem (BCSS). After adding the library, you must reinitialize the BCSS.
BMC152114S Load of <module> into the private area failed, R15(<return code>).
<subsysid>
Explanation: The Application Enhancement Solutions (AES) VSAM component
could not load the indicated module into the private area because storage was not
available.
System Action: Initialization terminates.
User Response: Verify that there is enough storage space in the private area
allocated for the BMC Software Consolidated Subsystem (BCSS). Verify the region
parameter on the BCSS procedure. If the problem persists, contact BMC Software
Product Support and provide the module and return code values.