HP (Hewlett-Packard) 50091 1-002 Cell Phone User Manual


 
HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 103
306 Informational An old serial number in SC flash memory has
been updated to a new serial number.
307 Critical A temperature sensor on a controller FRU
detected an over-temperature condition that
caused the controller to shut down.
Check that the storage system’s fans are
running.
Check that the ambient temperature is not
too warm. The enclosure operating range is
41 – 10 4 ° F (5–40° C).
Check for any obstructions to the airflow.
If none of the above explanations apply,
replace the controller FRU that reported the
error.
308 Informational The default host port speed has changed
from 4 Gbit/sec to 2 Gbit/sec because the
controller module’s HIM has a Broadcom
PBC.
309 Informational Normally when the MC is started, the IP data
is obtained from the SEEPROM where it is
persisted. If the system is unable to write it to
the SEEPROM the last time it changed, a flag
is set in flash memory. This flag is set during
startup, and if set, this event is logged and
the IP data that is in flash memory is used.
The only time that this would not be the
correct IP data would be if the controller
board was swapped and then whatever data
is on the board’s flash memory is used.
310 Informational After a rescan, the controller completed
back-end discovery and initialization of
enclosure data.
313 Critical An I/O module is down and will not be
automatically restarted. This only applies
when the other SC goes down.
The SC needs service or replacement.
314 Critical A FRU has failed or is not operating
correctly. This event follows some other FRU
specific event indicating a problem.
Examine the FRU specified in the message to
determine whether it needs to be replaced.
315 Critical The controller module is incompatible with
the enclosure. The controller will
automatically shut down. If two incompatible
controllers are inserted at the same time, or
booted at the same time, one controller will
crash and the other will hang. This behavior
is expected and prevents data loss.
Move the controller module to a compatible
controller.
316 Informational
or warning
The temporary license for a feature is about
to expire or has expired. This event is logged
as informational while time remaining in the
trial period is nonzero. This event is logged
as a warning when the trial period expires.
To continue using the feature after the trial
period, purchase a permanent license.
Table 14 Event code descriptions and recommended actions (continued)
Event
code
Event type Description Recommended action