HP (Hewlett-Packard) 50091 1-002 Cell Phone User Manual


 
HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 79
connUnitTable Includes the following objects as specified by the FA MIB2.2 Spec
connUnitId Unique identification for this
connectivity unit
Total of 16 bytes comprised of 8
bytes of the node WWN or similar
serial number-based identifier (for
example, 1000005013b05211) with
the trailing 8 bytes equal to zero
connUnitGlobalId Same as connUnitId Same as connUnitId
connUnitType Type of connectivity unit storage-subsystem[11]
connUnitNumports Number of host ports in the
connectivity unit
Number of host ports
connUnitState Overall state of the connectivity unit online[2] or unknown[1], as
appropriate
connUnitStatus Overall status of the connectivity unit ok [3], warning[4], failed[5], or
unknown[1], as appropriate
connUnitProduct Connectivity unit vendor’s product
model name
Model string
connUnitSn Serial number for this connectivity
unit
Serial number string
connUnitUpTime Number of centiseconds since the
last unit initialization
0 at startup
connUnitUrl Same as systemURL Same as systemURL
connUnitDomainId Not used; set to all 1s as specified by
the FA MIB2.2 Spec
0xFFFF
connUnitProxyMaster Stand-alone unit returns yes for this
object
yes [3] since this is a stand-alone unit
connUnitPrincipal Whether this connectivity unit is the
principal unit within the group of
fabric elements. If this value is not
applicable, returns unknown.
unknown[1]
connUnitNumSensors Number of sensors in the
connUnitSensorTable
33
connUnitStatusChangeTime Same as statusChangeTime Same as statusChangeTime
connUnitConfiguration
ChangeTime
Same as
configurationChangeTime
Same as
configurationChangeTime
connUnitNumRevs Number of revisions in the
connUnitRevsTable
16
connUnitNumZones Not supported 0
connUnitModuleId Not supported 16 bytes of 0s
connUnitName Settable: Display string containing a
name for this connectivity unit
Default: Uninitialized Name
connUnitInfo Settable: Display string containing
information about this connectivity
unit
Default: Uninitialized Info
connUnitControl Not supported invalid[2] for an SNMP GET
operation and not settable through
an SNMP SET operation.
Table 10 FA MIB 2.2 objects, descriptions, and values (continued)
Object Description Value