34 Configuring the system
Configuring email notification
To configure email notification of events
1. In the Configuration View panel, right-click the system and select Configuration > Services > Email
Notification.
2. In the main panel, set the options:
Notification Level. Select the minimum severity for which the system should send notifications:
Critical (only); Warning (and Critical); Informational (all). The default is none, which disables email
notification.
SMTP Server address. The IP address of the SMTP mail server to use for the email messages. If the
mail server is not on the local network, make sure that the gateway IP address is set in System
Settings > Network Interfaces.
Sender Name. The sender name that, with the domain name, forms the “from” address for remote
notification. Because this name is used as part of an email address, do not include spaces. If no
sender name is set, a default name is created.
Sender Domain. The domain name that, with the sender name, forms the “from” address for remote
notification. Because this name is used as part of an email address, do not include spaces. If no
domain name is set here, the default domain value is used. If the domain name is not valid, some
email servers will not process the mail.
Email Address fields. Up to four email addresses that the system should send notifications to. Email
addresses must use the format user-name@domain-name.
3. Click Apply.
Configuring SNMP notification
To configure SNMP notification of events
1. In the Configuration View panel, right-click the system and select Configuration > Services > SNMP
Notification.
2. In the main panel, set the options:
Notification Level. Select the minimum severity for which the system should send notifications:
Critical (only); Warning (and Critical); Informational (all). The default is none, which disables
SNMP notification.
Read Community. The SNMP read password for your network. The value is case sensitive. The
default is public.
Write Community. The SNMP write password for your network. The value is case sensitive. The
default is private.
Trap Host Address fields. IP addresses of up to three host systems that are configured to receive
SNMP traps.
3. Click Apply
Configuring user accounts
Adding users
To add a user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Add User.
2. In the main panel, set the options:
User Name. A user name is case sensitive and cannot already exist in the system. A name cannot
include a comma, double quote, or backslash.
Password. A password is case sensitive. A password cannot include a comma, double quote, or
backslash. Though optional, passwords are highly recommended to ensure system security.
Access Level. Select Monitor to let the user view system settings, or Manage to let the user view and
change system settings.