HP (Hewlett-Packard) 50091 1-002 Cell Phone User Manual


 
HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 111
6. Quit the FTP session.
7. If the updated disks must be power cycled:
a. Shut down both controllers by using SMU.
b. Power cycle all enclosures as described in your product’s user guide.
NOTE: If you loaded firmware to a Seagate 750-Gbyte Barracuda ES SATA drive, after spin-up it
will be busy for about 50 seconds completing its upgrade. Then it will be ready for host I/O.
8. In SMU, verify that each disk has the correct firmware revision.
9. Resume host I/O.
Installing a license file
1. Ensure that the license file is saved to a network location that the storage system can access.
2. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the directory
containing the firmware file to load.
3. Log in to the controller enclosure that the file was generated for:
ftp controller-network-address
For example:
ftp 10.1.0.9
4. Log in as an FTP user.
5. Enter:
put license-file license
For example:
put certificate.txt license
A message confirms whether installation succeeded or failed. If installation succeeds, licensing
changes take effect immediately.