86 SNMP reference
FROM RFC-1215
connUnitEventId, connUnitEventType, connUnitEventDescr
FROM FA-MIB40;
--Textual conventions for this MIB
----------------------------------------------------------------------
-- vendor
hp OBJECT IDENTIFIER ::= { enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
hpMSA OBJECT IDENTIFIER ::= { nm 51 }
-- Related traps
msaEventInfoTrap TRAP-TYPE
ENTERPRISE hpMSA
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): info"
-- Trap annotations are as follows:
--#TYPE "Informational storage event"
--#SUMMARY "Informational storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 6
::= 3001
msaEventWarningTrap TRAP-TYPE
ENTERPRISE hpMSA
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): warning"
-- Trap annotations are as follows:
--#TYPE "Warning storage event"
--#SUMMARY "Warning storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY MINOR
--#TIMEINDEX 6
::= 3002
msaEventErrorTrap TRAP-TYPE
ENTERPRISE hpMSA
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): error"