HP (Hewlett-Packard) 50091 1-002 Cell Phone User Manual


 
104 Event code reference
322 Warning The controller has an older SC version than
the version used to create the CHAP
authentication database in the controller’s
flash memory.
The CHAP database cannot be read or
updated. However, new records can be
added, which will replace the existing
database with a new database using the
latest known version number.
Upgrade to an SC version that is current for
the indicated database version.
If no records were added, the database
becomes accessible and remains intact.
If records were added, the database
becomes accessible but contains only
the new records.
352 Informational EC assert data or stack-dump data is
accessible.
353 Informational EC assert data and stack-dump data have
been cleared.
354 Informational
or warning
SAS topology has changed on a host port.
For example, the SAS cable connecting a
controller host port to a host has been
disconnected. This event is logged as
informational for a topology change where
at least one PHY goes “up.” This event is
logged as a warning for a topology change
where at least one PHY goes “down.”
355 Warning The faceplate's debug button was found to
be stuck in the On position during boot up.
412 Warning One disk in the specified RAID-6 vdisk failed.
The vdisk is operational with Degraded
health and status FTDN (fault tolerant with a
down disk).
Replace the down disk with a spare so the
system can start reconstructing the vdisk.
443 Warning A firmware version mismatch has been
detected in an MSA70 drive enclosure. The
enclosure should be updated to the latest
supported version of firmware as soon as
possible.
In the drive enclosure all FRUs (I/O module,
fan, power supply, midplane, backplane,
and 7-segment LED) must be at a combined
proper firmware recipe. The two I/O
modules must be at equal firmware versions.
Any replaced MSA70 FRUs might have older
firmware that does not match an internally
defined recipe. Update the drive enclosure to
the latest firmware version to ensure all FRUs
are at the proper firmware level.
Table 14 Event code descriptions and recommended actions (continued)
Event