A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
112 Application Enhancement Solutions Messages Manual
BMC48002I BCF LOG UTILITY; END LOG TAPE EXTRACT PHASE #
Explanation: The Online Backout Log Create (
OCREATE) function has finished
extracting log records for the requested program specification block (PSB) and unit
of work (UOW).
System Action: Processing continues for the next request.
User Response: This message is for your information only. No action is necessary.
BMC48003I NO PSB NAME SPECIFIED FOR CREATE REQUEST
Explanation: An Online Backout Log Create (
OCREATE) request is being
processed, but the request did not contain a valid program specification block (PSB)
name.
System Action: The
OCREATE request ends with return code 7.
User Response: Correct the
OCREATE control statement and resubmit the job.
BMC48004I LOG RECORD SEQUENCING INCORRECT
Explanation: While processing the input log data set during extract processing,
the BATCH CONTROL FACILITY (BCF) Log utility detected a sequence error in
the IMS log record sequence field.
System Action: The
OCREATE request ends with return code 7.
User Response: Correct the problem with the IMS log data set used as input to the
OCREATE request. If the data set is a multi-volume data set, verify that all necessary
volumes are present and in the correct sequence, and resubmit the job.