BMC Software, Inc., Confidential and Proprietary Information
116 Application Enhancement Solutions Messages Manual
BMC48014I PSB EXECUTION DID NOT TERMINATE NORMALLY
Explanation: The IMS log record representing the end of the program
specification block (PSB) execution being extracted indicates that the PSB execution
terminated abnormally.
System Action: The Online Backout Log Create (
OCREATE) request ends with
return code 7.
User Response: Determine whether batch backout has been performed and evaluate
the effect it could have on the
OCREATE function.
BMC48015I RETURN CODE FROM UTILITY REQUEST =rc
Explanation: The requested utility function has completed. The message
provides the return code (rc) provided by the request.
System Action: Processing continues.
User Response: Verify the return code.
BMC48016I UTILITY EXECUTING ON UNAUTHORIZED PROCESSOR, EXECUTION
ENDED
Explanation: BATCH CONTROL FACILITY (BCF) is not authorized for
execution on the processor, or the trial period has expired.
System Action: The BCF Log utility execution terminates with a U4016 abend.
User Response: Correctly authorize the processor using the CPU ID authorization
function available from the Application Enhancement Series primary menu, or
contact your BMC Software sales representative for assistance.
BMC48017I RDJFCB FAILED FOR DDNAME ddname
Explanation: A nonzero return code was received from the MVS RDJFCB
macro.
System Action: The BATCH CONTROL FACILITY (BCF) Log utility execution
terminates with a U4017 abend.
User Response: Verify the existence of the data set associated with ddname. Have
the BCF Log utility job log data set available if you need to contact BMC Software
Product Support for assistance.