BMC150100BMC150199
BMC150100I CURSOR REPOSITIONING HAS BEEN PERFORMED FOR CURSOR
cursorname
Explanation: APPLICATION RESTART CONTROL (AR/CTL) has
performed cursor repositioning for the indicated cursor.
System Action: Processing continues.
User Response: This message is for your information only. No action is required.
BMC150101E AUTO RESTART AND AUTO CHECKPOINT MUST BE SET TO THE
SAME VALUE FOR AN IMS EXECUTION.
Explanation: The Automatic Restart option and the Automatic Checkpoints
option both must be set to Y or both to N for an IMS execution.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Make sure that the Automatic Restart option is set to the same
value as the Automatic Checkpoints option in an IMS environment.
BMC150102E MAXIMUM LENGTH EXCEEDED FOR SKELETON (datasetname).
Explanation: The maximum length of 44 characters for a data set name has been
exceeded during substitution operation for the dynamic allocation skeleton or
concatenation list entry.
System Action: The task terminates abnormally with abend U1771 and reason code
X'00150102'.
User Response: Correct the dynamic allocation skeleton or concatenation list entry,
and resubmit the job.