BMC Software, Inc., Confidential and Proprietary Information
Abend Codes 9
U623 or U1569 The BATCH CONTROL FACILITY (BCF) Physical Logger was not able to
initialize. The Physical Logger Error option was specified as ABEND. The abend
code displayed depends on the value specified for the Use Abend Code Series option.
For more information, see the Use Abend Code Series (ABN) option in the BATCH
CONTROL FACILITY Reference Manual.
System Action: This is a BCF Physical Logger internal error.
User Response: Refer to messages in the job log for an indication of the problem. If
you cannot determine the reason for the abend, ensure that a SYSUDUMP and the
job log listings are available and contact BMC Software Product Support.
U624 or U1570 The execution controller could not establish a restartable environment for the job
step. The abend code displayed depends on the value specified for the Use Abend
Code Series (ABN) option. For more information, see the Use Abend Code Series
option in the BATCH CONTROL FACILITY Reference Manual.
System Action: The job log for this execution contains messages about the error(s)
encountered.
User Response: Manual intervention is required. Correct the errors, update the
REGISET to reflect changes that result from actions (log closure, backout, etc.)
taken to correct the error(s), and restart the job step.
U625 or U1571 The execution controller has encountered an error that prevents further execution.
The abend code displayed depends on the value specified for the Use Abend Code
Series (ABN) option. For more information, see the Use Abend Code Series option
in the BATCH CONTROL FACILITY Reference Manual.
System Action: The job log for this execution contains messages about the error(s)
encountered.
User Response: Manual intervention is required. Correct the errors, update the
REGISET to reflect changes that result from actions (log closure, backout, etc.)
taken to correct the error(s), and restart the job step.
U626 or U1572 The BATCH CONTROL FACILITY (BCF) Physical Logger has encountered an
unrecoverable error during initialization. The abend code displayed depends on the
value specified for the Use Abend Code Series (ABN) option. For more information,
see the Use Abend Code Series option in the BATCH CONTROL FACILITY
Reference Manual.
System Action: The initialization routine could not locate the directory module
(BECDIR) containing the execution defaults. Control could not be returned to the
IMS Physical Logger because module DFSXLGI0 could not be located.
User Response: Restart the job step, making certain that the modules necessary for
execution are available.