BMC Software, Inc., Confidential and Proprietary Information
280 Application Enhancement Solutions Messages Manual
BMC93010E CICS MIRROR TRANSACTION IS DOWN, CICS APPLID=appl status,
TRANID=tran status
Explanation: An attempt by APPLICATION RESTART CONTROL (AR/CTL)
to send a VSAM file sharing request to CICS failed because the CICS mirror
transaction was not available. This message indicates the appl status of the APPLID,
and the tran status of the TRANID, associated with the requested CICS region.
System Action: AR/CTL terminates the task abnormally with abend 1711 and
reason code X00093010.
User Response: Restart the CICS environment, and resubmit the job step.
BMC93011E INTERNAL ERROR IN FORMAT 1 TRANSFORMER, RC=rc
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected an
internal error in the Format 1 transformer and returned the specified return code (rc).
System Action: AR/CTL terminates the task abnormally with abend 1711 and
reason code X00093011.
User Response: Call BMC Software Product Support for assistance.
BMC93012E GETMAIN ERROR IN FORMAT 1 TRANSFORMER, RC=rc
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected a
GETMAIN error in the Format 1 transformer and returned the specified return code
(rc).
System Action: AR/CTL terminates the task abnormally with abend 1711 and
reason code X00093012.
User Response: Call BMC Software Product Support for assistance.
BMC93013E FREEMAIN ERROR IN FORMAT 1 TRANSFORMER, RC=rc
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected a
FREEMAIN error in the Format 1 transformer and returned the specified return code
(rc).
System Action: AR/CTL terminates the task abnormally with abend 1711 and
reason code X00093013.
User Response: Call BMC Software Product Support for assistance.