A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
BMC74300BMC74399 237
12 The job step was restarted after VSAM component termination had been
attempted in a previous execution. VSAM component termination failed.
Review the previous execution to determine the nature of the error. The data
sets may need to be backed out or recovered manually, and the VSAM
recovery record must be deleted from the REGISET before the job is
restarted.
13 The job step was restarted after VSAM component termination had been
attempted in a previous execution. VSAM component termination was not
completed. Review the previous execution to determine the nature of the
error. The data sets may need to be backed out or recovered manually, and
the VSAM recovery record must be deleted from the REGISET before the
job is restarted.
14 The job step was restarted after VSAM component backout had been
attempted in a previous execution. VSAM component backout failed and
will not be retried. The data sets must be backed out or recovered manually,
and the VSAM recovery record must be deleted from the REGISET before
the job is restarted.
15 The job step was restarted after VSAM component backout had been
attempted in a previous execution. VSAM component backout was not
completed and will not be retried. The data sets must be backed out or
recovered manually, and the VSAM recovery record must be deleted from
the REGISET before the job is restarted.
16 During restart processing, an error occurred while AR/CTL was trying to
update the VSAM recovery record in the REGISET. The data sets must be
backed out or recovered manually, and the VSAM recovery record must be
deleted from the REGISET before the job is restarted.
17 During restart processing, VSAM component backout was invoked for
backout. The backout did not execute successfully, and an error occurred
while AR/CTL was trying to update the VSAM recovery record in the
REGISET. The data sets must be backed out or recovered manually, and the
VSAM recovery record must be deleted from the REGISET before the job
is restarted.
18 During restart processing, VSAM component backout could not be executed
successfully. If restart processing is allowed to continue without backout
executing successfully, data integrity could be jeopardized. Backout must be
executed successfully before restart continues.
System Action: AR/CTL terminates the job step abnormally with abend U1578.
User Response: Review the sections of the APPLICATION RESTART CONTROL
User Guide that discuss problem solving, perform the appropriate procedure, and
update the REGISET. Review the other messages in the job log data set for the job
step execution that failed. The problem determination and recovery actions taken
depend on the errors indicated by these messages. If you need to contact BMC
Software Product Support for assistance, have the job log data set available.