BMC Software, Inc., Confidential and Proprietary Information
BMC44200–BMC44299 81
BMC44213I BCF LOGGER DBRC ERROR, FUNC = func, RC = rc
Explanation: The BATCH CONTROL FACILITY (BCF) Physical Logger has
received a nonzero return code from DBRC while attempting to notify DBRC of a
change in the status of a log data set volume. The func in error and the DBRC return
code (rc) appear in the message. The following function codes are possible:
OPEN log data set open
CLOSE
log data set close
EOV processing EOV (end-of-volume) for log data set
SYNAD
synchronous exit
BUILD initializing the DBRC environment
REORG
notifying DBRC of reorganization
BOERR
notifying DBRC of batch backout error
BDORG
build parameter for
REORG
BDBBO
build parameter for batch backout
INBBO
initializing for batch backout
EJBBO
end of job for batch backout
System Action: The action taken depends on the routine that detects the error. If
the routine is log data set notification, the job step terminates. If the routine is discard
logging database processing, processing continues.
User Response: Have the job log data set available if you need to contact BMC