BMC Software, Inc., Confidential and Proprietary Information
208 Application Enhancement Solutions Messages Manual
BMC74259W PARSED COMMAND nn LENGTH length TOKEN token LENGTH length
TOKEN token
Explanation: APPLICATION RESTART CONTROL (AR/CTL) issues this
message to accompany message BMC74176W or BMC74177W, which report that
AR/CTL found an error in a command. This message displays the parsed command,
including the number of the command (nn) and the length and token of each part of
the command.
System Action: AR/CTL also issues message BMC74176W or message
BMC74177W, whichever is appropriate. Processing continues.
User Response: Correct and re-enter the command.
BMC74260E RESTART DATA SET (restart.dsn) IDCAMS LISTCAT COMMAND
RETURNED CODE (rc)
Explanation: APPLICATION RESTART CONTROL (AR/CTL) issued the
IDCAMS
LISTCAT command to list the catalog entry for the given restart data set
(restart.dsn). The command failed, and AR/CTL received return code rc.
System Action: Processing continues.
User Response: To determine the corrective action to take, examine the alternate
SYSPRINT data set (found under the ddname ARCDIVPR) for the IDCAMS
LISTCAT command. Analyze the listing of the restart data set catalog entry to
determine whether to modify the dynamic allocation skeleton for the restart data set.
BMC74261E UNABLE TO LOCATE {PSB psbname | ASB asbname}
Explanation: APPLICATION RESTART CONTROL (AR/CTL) could not
locate the given PSB (psbname) in the IMS DD statement concatenation, or it could
not locate the given ASB (asbname) in the ARC DD statement concatenation.
System Action: The job step terminates abnormally with abend U1553.
User Response: Make sure that the PSB or ASB name is spelled correctly. Make
sure that the correct PSB or ASB library is specified.
BMC74262E UNABLE TO LOCATE {DBD dbdname | FCB fcbname}
Explanation: APPLICATION RESTART CONTROL (AR/CTL) could not
locate the given DBD (dbdname) in the IMS DD statement concatenation, or it could
not locate the given FCB (fcbname) in the ARC DD statement concatenation.
System Action: The job step terminates abnormally with abend U1553.
User Response: Make sure that the DBD or FCB name is spelled correctly. Make
sure that the correct DBD or FCB library is specified.