A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
8 Application Enhancement Solutions Messages Manual
U618 or U1564 The BATCH CONTROL FACILITY (BCF) Physical Logger end-of-volume (EOV)
routine was entered with an invalid address. The abend code displayed depends on
the value specified for the Use Abend Code Series (ABN) option. For more
information, see the Use Abend Code Series option in the BATCH CONTROL
FACILITY Reference Manual.
System Action: This is a system error.
User Response: Ensure that a SYSUDUMP and the job log listings are available
and contact BMC Software Product Support.
U619 or U1565 The BATCH CONTROL FACILITY (BCF) Physical Logger initialization detected
an invalid IMS release level during initialization. The abend code displayed depends
on the value specified for the Use Abend Code Series (ABN) option. For more
information, see the Use Abend Code Series option in the BATCH CONTROL
FACILITY Reference Manual.
System Action: This is a system or installation error.
User Response: Verify that the level of IMS being used is a supported level. If it is,
ensure that a SYSUDUMP and the job log listings are available and contact BMC
Software Product Support.
U620 or U1566 The BATCH CONTROL FACILITY (BCF) Physical Logger
READ routine was
unable to open any of the IMS log data sets for
READ processing. The abend is
produced so that the execution controller, if active, will attempt IMS batch backout.
The abend code displayed depends on the value specified for the Use Abend Code
Series (ABN) option. For more information, see the Use Abend Code Series option
in the BATCH CONTROL FACILITY Reference Manual.
System Action: This is a system or installation error.
User Response: Determine why the open process failed. If you are unable to
determine why this abend occurred, ensure that a SYSUDUMP data set, a job step
dump, and the job log listings are available and contact BMC Software Product
Support.
U621 or U1567 BATCH CONTROL FACILITY (BCF) has determined that the execution controller
aborted processing because of an unrecoverable error. The abend code displayed
depends on the value specified for the Use Abend Code Series option. For more
information, see the Use Abend Code Series (ABN) option in the BATCH CONTROL
FACILITY Reference Manual.
System Action: A resource necessary for step execution has become unavailable.
User Response: Review the job log for indications of the error condition, correct
the error condition, and update the prior execution status to indicate the repair action
that was taken.