Furuno FS-2570 (150W) Cell Phone User Manual


 
7 DSC/WATCH RECEIVER SETUP
7-4
7.4 Setting Scan Frequencies
The Scan freq menu determines which DSC routine and distress frequencies to scan.
Follow the instructions below to select/deselect DSC routine and distress frequencies to
scan.
7.4.1 Distress frequencies
1. Press the [#/SETUP] key at the DSC standby screen, choose SCAN FREQ and then
push the [ENTER] knob to display the SCAN FREQ menu.
DISTRESS
2M :
FIXED
4M :
ON
6M : ON
8M :
FIXED
12M : ON
16M : OFF
**
Scan freq setup
*
ROUTINE
F1 : 2M-INTL
F2 : 4M-INTL
F3 : 6M-INTL
F4 : 8M-INTL
F5 : 12M-INTL
F6 : 16M-INTL
2. Rotate the [ENTER] knob clockwise to shift the cursor to the DISTRESS column.
3. Rotate the [ENTER] knob to choose the frequency to process and then push the
[ENTER] knob. For example, choose 4 MHz.
ROUTINE
F1 : 2M-INTL
F2 : 2M-INTL
F3 : 4M-INTL
F4 : 8M-INTL
F5 : 12M-INTL
F6 : 16M-INTL
DISTRESS
2M :
FIXED
4M : ON
6M : ON
8M :
FIXED
12M : ON
16M : OFF
**
Scan freq setup
*
OFF
ON
4. Rotate the [ENTER] knob to choose ON or OFF as appropriate and then push the
[ENTER] knob.
5. Press the [CANCEL] key twice to return to the DSC standby screen.
Note: Regulations require that 2 MHz and 8 MHz and one more DSC distress frequency
be watched continuously. These frequencies cannot be turned off. Maximum three
bands may be turned off.
7.4.2 Routine frequencies
1. Press the [#/SETUP] key, choose SCAN FREQ and then push the [ENTER] knob to
display the Scan freq menu.
DISTRESS
2M :
FIXED
4M :
ON
6M : ON
8M :
FIXED
12M : ON
16M : OFF
**
Scan freq setup
*
ROUTINE
F1 : 2M-INTL
F2 : 4M-INTL
F3 : 6M-INTL
F4 : 8M-INTL
F5 : 12M-INTL
F6 : 16M-INTL
2. Rotate the [ENTER] knob to choose the frequency to process and then push the
[ENTER] knob. For example, choose F1: 2 M-INTL.