OnCell G2150I AT Command Set GPRS Commands
10-19
GPRS Parameter Customization: + WGPRS
Description: This command modifies some G2150I GPRS parameters:
the ATTACH-STATUS (the ME does or not perform automatically a GPRS
attachment after initialization),
the PDP-INIT-STATUS (activates automatically or not some defined PDP contexts
after initialization) and
the user-defined multislot class. This parameter represents the GPRS class chosen by
the user to perform power saving (by reducing TX (or uplink) time slots).
In addition, this command allows:
set automatically “ACTIVABLE” some defined PDP contexts after initialization
set some parameters for PALM® OS software: PPP Silent Mode (PPP waits for PPP
Client to start the dialog) and Slow CONNECT (due to the delay of the processing
of PALM® OK, the CONNECT is sent one second after the dialing command
request)
IMPORTANT NOTE: The G2150I must be rebooted to activate the new setup except
for <mode> 3, 5, 6 and 7 (please refer to Defined Values paragraph).
Command syntax: AT+WGPRS=<mode>,<parameter>,[<cid>],[<class>]
Command Possible responses
AT+WGPRS=? +WGPRS: <mode>,
<parameter1>,[<cid>]
[<CR><LF>+WGPRS:
<mode>,
<parameter>,[<cid>]
[...]]
OK
AT+WGPRS? +WGPRS:<mode>(list of supported
<parameter>),[(list of
supported
<cid>)][<CR><LF>+WGPR
S:<mode>(list of
supported
<parameter>),[(list of
supported <cid>)] [...]]
OK
AT+WGPRS=2,1,3
Note: set ACTIVABLE to ON on PDP
context 3
OK
AT+WGPRS=7,1
Note: set automatic re-attachment to the
network and reactivation of PDP context
in case of change of operator for
MCC/MNC
OK
AT+WGPRS=4,,,8
Note: choose GPRS multislot class 8
OK
AT+WGPRS=?
Note: Request ranges of values
+WGPRS: (0-7),(0-1),(0-
4),(2,8,10, 12)
OK