Moxa Technologies G2150I Carrying Case User Manual


 
OnCell G2150I AT Command Set Network Service Commands
5-4
AT+COP S=2
Note: Ask for deregistration from network
OK
Note: Succeeded
AT+COP S?
Note: Ask for current PLMN
+COPS: 2
Note: ME is unregistered until <mode>=0
or 1 is selected
Defined values:
<mode>
0: automatic (default value)
1: manual
2: deregistration; ME will be unregistered until <mode>=0 or 1 is selected.
3: set only <format> (for read command AT+COPS?)
4: manual / automatic (<oper> shall be present), if manual selection fails, automatic
mode is entered.
<format>: format of <oper> field
0: long alphanumeric format <oper>
1: short alphanumeric format <oper>
2: numeric <oper> (default value)
<stat>: status of <oper>
0: unknown
1: available
2: current
3: forbidden
<oper>: operator identifier (MCC/MNC in numeric format only for operator selection) The
long alphanumeric format can be up to 16 characters long (see appendix 19 Codes and values
for operator names description, field is “Name”). The short alphanumeric format can be up to
10 characters long.
Network Registration: +CREG
Description: This command is used by the application to ascertain the registration status of the
product.
Command syntax: AT+CREG= <mode>
+CREG: <mode>, <stat> [ ,<lac>,<ci> ] for AT+CREG? command only
Command Possible responses
AT+CREG? +CREG: <mode>,<stat>
OK
Note: As defined here-above
AT+CREG=0
Note: Disable network registration unsolicited
result code
OK
Note: Command valid
AT+CREG=1
Note: Enable network registration unsolicited
result code
OK
Note: Command valid
AT+CREG=2
Note: Enable network registration and location
information unsolicited result code
OK
Note: Command valid
AT+CREG=? +CREG: (0-2)
Note: 0,1,2 <mode> values are supported
Defined values:
<mode>