Moxa Technologies G2150I Carrying Case User Manual


 
OnCell G2150I AT Command Set GPRS Commands
10-21
some OS-specific frames, for accurate transfer rate measurements.
<parameter>: a numeric parameter that controls the operation defined by <mode> if it is
equal to 0, 1, 2, or 3.
0 operation OFF (disabled)
1 operation ON (enabled)
<cid>: (PDP Context Identifier)a numeric parameter that specifies a particular PDP context
definition. The parameter is local to the TE-MT interface and is used in other PDP
context-related commands. Range of values is 0 to 4.
<class>: GPRS multislot class number. It may be lower than the maximum possible class.
Possible value are 2, 8, 10, 12. Refer to doc ref [6] for more information about
GPRS multislot classes.
Multislot
class
Maximum number of
slots
Minimum number of slots Type
of MS
Rx Tx Sum
T
ta
T
tb
T
ra
T
rb
2
8
2
4
1
1
3
5
3
3
2
1
3
2
1
1
1
1
10
4
2
5
3
1
2
1
1
12
4
4
5
2
1
2
1
1
NB: Type 1 MS are not required to transmit and receive at the same time
Remark: When the G2150I is set in “CG” class, the ME always make automatically a GPRS
attachment after init, so AT+WGPRS? always give +WGPRS: 0,0 for the parameter 0.
Note: Default value for mode 7 is 0; in this case, no automatic GPRS reconnection to new
operator is done when reaching border areas.
Full AT GPRS Command Examples
Activation of an IP PDP context :
Example 1:
AT+CGPDCONT=1,”IP”,”internet”; +CGDCONT=2,”IP”,”abc.com”
OK
ATD*99***1#
CONNECT