HP (Hewlett-Packard) E6380-90019 Cell Phone Accessories User Manual


 
Chapter 5 139
Analog Measurements - Screens and Control Fields
Marker To Peak+ Marker To (spectrum analyzer)
Marker To Peak+
Peak+ causes the marker to move to the maximum value of the average
level measured on the display.
Because this functions look at the average value for each displayed
pixel, the marker may not appear directly on the displayed peak of a
noisy signal.
Screens on which this field is displayed
SCOPE: marker controls menu
Marker To Peak-
Peak causes the marker to move to the minimum value of the average
level measured on the display.
Because this functions look at the average value for each displayed
pixel, the marker may not appear directly on the displayed peak of a
noisy signal.
Screens on which this field is displayed
SCOPE: marker controls menu
Marker To (spectrum analyzer)
These two fields position the marker as follows.
Peak moves the marker to the highest peak and enters the location
in the Position field.
Next Peak moves the marker to the next peak to the right and
enters the location in the Position field.
Center Freq changes the center frequency value to match the
current position of the marker.
Ref Level changes the reference level setting to match the current
position of the marker.
Screens on which this field is displayed
SPEC ANL: marker controls menu