Connect the music source to the music ampli-
fier input.
Connect the paging amplifier outputs to PIOU
(PGIN) relays
Kl - K4
and zone A - zone D
speakers (C).
Connect the music amplifier (+) output to
terminal 23 (PG COMMON) of the PIOU, and
the (-) output to the “C” terminal of zone A -
zone D speakers.
Connect zone A - zone D speakers “A” termi-
nal to the “PGOUT” contact of the PIOU relays
Kl - K4 respectively.
5.16 DK16 Night Ringing over All External Page
Zones (PIOU only).
To allow the night ringing sig-
nal to be sent over zone paging, install the paging
amplifier in accordance with the following steps
(refer to Figure 7-18). (Steps 2 - 6 are performed at
the MDF.)
IMPORTANT NOTE: To night ring over
selected PAGE zone, see Paragraph 9 of this
section.
1)
2)
3)
4)
5;
6)
7)
Connect the amplifier input via an RJl 1 jack to
the J7 600 ohm Page RCA jack on the Base
unit. Or, direct connect J7 to Amp using a
standard audio cable with RCA plugs.
Cross-connect the amplifier output A to the
PGINl - PGIN4 connector from the PIOU.
Cross-connect the amplifier output B to the
zone A - zone D speaker common line.
Cross-connect the PIOU PGOUTl - PGOUT4
to zone A - zone D speakers (A).
Cross-connect the amplifier output A to pin 9
(NHR) of the PIOU.
Cross-connect a jumper from pin 34 (NHT) to
pin 23 (PG COMMON) from the PIOU PCB.
In
Program 77-1,
set
LED
05
to OFF
and 06
to
ON.
Set
LED
08 to ON if door phones are to
ring over external page when the system is in
NIGHT mode.
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
8)
In
Program
78, enable the CO lines that are to
ring via external page when the system is set
in the NIGHT mode.
9)
In
Program
39, assign the Night Transfer
1 or Night Transfer 2 buttons to digital or
electronic telephones per the System Record
Sheets (see Note 2).
10) Press the Night Transfer 1 or Night
Transfer 2 button on an electronic or digital
telephone to set the system into the NIGHT
mode. Test by calling into the system on a CO
line assigned
(Program
78) to night ring over
external page.
l
When ringing sounds (see Note 2) over
the page, press Intercom 5 3 5 to
answer.
NOTES:
1.
2.
All zones will ring with this option; night
ringing to selected zones is not possible;
see paragraph 9 for night ring over se-
lected page zones.
The Night Transfer 1 or Night
Transfer 2 buttonsput CO linesin NIGHT
ring mode per Program 15; NTl-TEN-
ANT VNTZ-TENANT 2 CO line assign-
ment.
6 DK8 AND DK16 STATION MESSAGE
DETAIL RECORDING (SMDR) PRINTER/
CALL ACCOUNTING DEVICE OPTIONS
6.00 An SMDR printer or call accounting device
may be connected to the system to provide a hard-
copy record of station activity (incoming, outgoing,
and transferred calls account code entries) on CO
lines or a printout of the customer data base. Call
record data is printed out at the completion of each
call. Program SMDR with
Program
60, and use
Program
97 to have the SMDR printer display the
customer data base.
6.01 SMDR will send out special names for the
following types of calls:
l
MSS:
Prints on DlSAcalls to stations (see Note).
l
MODM:
Prints on calls to the IMDU remote
maintenance modem (station 619).