Toshiba STRATA DK16 Cell Phone User Manual


 
SELECT = Logical
Port Number
/NT = Station Number
NOTE: Shaded areas apply to DK16 only
DK16 - 8-Digit Ports from Base
DK8 - first QCDU
DK8 - second QCDU
from DK8 QSTU.
Expansion Unit. (DKI 6 only)
Only one type of circuit card
1 -PDKU, or I-PEKU, or 1 -PESU,
or 1 -PSTU or 2-KCDU
19 l(29)
1 (1%
I I
DK16 Expansion Unit Station PCB Typed , Slot NO(S) ___
PDKU (1, PEKU (/,I St KCDU (1,2nd KCDU (, PSTU m, PESur
NOTE:
Peripheral Device
Port Options: Devices other than telephones or Data interface Units can be connected to the
ports listed below. If a peripheral device is connected to a Physical Port, the Logical Port must have same pot7 no.
as the Physical Port.
l
Port 00 - DK16 - Digital telephone associated with DSS Console.
l
Port 02 and 03 - DK8 - Digital Door Phone/Lock Control Unit (DDCB).
l
PortO4-DK16- Digital Door Phone/Lock Control Unit (DDCB).
l
Port 07 - DK16 - Digital Direct Station Selection Console [DDSS).
l
Port lo-DK8- DISA Port number used for Toll Restriction Class and Verified/Forced Account Code
assignment.
l
Portll-DK16- Separate Background Music Source (KSTU required in Base Unit).
l
Port 12 - DK16 - Digital telephone associated with DSS Console (PDKWExpansion Unit required) or DDCB.
l
Port 12 - DK16 - Electronic telephone associated with DSS Console (PEKU/Expansion Unit required).
l
Port 14 or 19 - DK16 - Separate Background Music Source (PEKU, PESU, or PSTWExpansion Unit
required).
l
Port 17& 18-DK16- PESU or PEKU ports connected to external amplifier to provide external amplified
conference and /or DISA.
l
Port 18& 19-DK16-
Electronic Direct Station Selection console {HDSS) (PEKWExpansion Unit required).
l
Port 19 - DK16 - Digital Direct Station Selection console (DDSS) (PDKWExpansion Unit required).
l
Port20- DK16- DISA Port number used for Toll, Class and Verified/Forced Account Code assignments.
PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 100-816-302
MARCH 1993
PROGRAM 04
LOGICAL PORT INTERCOM NUMBER ASSIGNMENT
2-50