A SERVICE OF

logo

No. 99MBC071A
vii
4.1.2.5 Selecting and setting the function in the B4 mode .............. 4-14
a. Setting the use of RS-232C port (Guidance: RS-232C). 4-14
b. Setting the RS-232C communication baud rate
(Guidance: BAUD) ........................................................... 4-14
c. Setting the RS-232C communication data bits
(Guidance: LENGTH) ...................................................... 4-14
d. Setting the RS-232C communication parity bit
(Guidance: PARITY)........................................................ 4-15
e. Setting the delimiter for communication
(Guidance: DELIMT)........................................................ 4-15
f. Setting the RS-232C line control
(Guidance: CONTRL) ...................................................... 4-15
4.1.2.6 Selecting and setting the function in the B5 mode .............. 4-16
a. Setting the RUN input function from the I/O interface
(Guidance: RUN) ............................................................. 4-16
b. Setting the OFFS input function from the I/O interface
(Guidance: OFFS) ........................................................... 4-16
c. Setting the GO output function from the I/O interface
(Guidance: GO) ............................................................... 4-17
4.1.2.7 Selecting and setting the function in the B6 mode .............. 4-17
a. Setting the use of DCU (Guidance: DCU) ...................... 4-17
4.2 Calibration ................................................................................................... 4-18
4.2.1 Calibration gages and gage stand ................................................. 4-18
4.2.2 Entering the calibration mode......................................................... 4-18
4.3 Positioning a Gage or a Workpiece............................................................ 4-22
4.4 How to read-in the amount of light ............................................................. 4-22
4.5 Setting Up the Functions ............................................................................ 4-23
4.5.1 Outline of the function setup mode ................................................ 4-23
4.5.2 Outline of each function setup mode ............................................. 4-25
4.5.3 Function setup mode ...................................................................... 4-26
4.5.3.1 F0: Setting the segment ....................................................... 4-26
4.5.3.2 F1: Setting the measurement interval (measurement time) 4-28
4.5.3.3 F2: Setting the GO/NG judgment criteria ............................. 4-30
4.5.3.4 F3: Setting the reference value ............................................ 4-34
4.5.3.5 Analog voltage output and scale value ................................ 4-35
4.5.3.6 F4: Setting the offset value .................................................. 4-37
4.5.3.7 F5: Setting the data output conditions ................................. 4-39
4.5.3.8 F6: Setting the sample measurement .................................. 4-40
4.5.3.9 F7: Automatic workpiece detection setting .......................... 4-41
4.5.3.10 F8: Setting the group judgment............................................ 4-42
4.5.3.11 Confirming the function setup contents................................ 4-43
5. MEASUREMENT MODE ...................................................................................... 5-1
5.1 Outline of the Measurement Mode ............................................................... 5-1
5.1.1 Settings made in the measurement mode ....................................... 5-1
5.1.1.1 Setup operation from the arrow key....................................... 5-2
5.1.1.2 Setup that can be made directly from each setup item key .. 5-4
5.2 Other Functions ............................................................................................ 5-5
5.2.1 Key lock ............................................................................................ 5-5
5.2.2 Displaying the measuring position.................................................... 5-5