NEC NDA-24305 Cell Phone User Manual


 
NDA-24305 CHAPTER 5
Page 119
Revision 1.0
NIGHT CONNECTION OUTSIDE-SYSTEM-PRI
N-29 NIGHT CONNECTION OUTSIDE-SYSTEM-PRI
1. General Description
This is a night transfer service on a system basis enabling a ring down call to be transferred to a preselected
station outside the PBX via ISDN network when Night mode has been set.
2. Operating Procedure
1. The Attendant sets Night mode.
(Night key, PB, Jack Extraction, MB)
2. Ring down call terminates from a trunk.
3. The call is transferred to another station in accordance with NIGHT CONNECTION OUTSIDE-SYSTEM-
PRI data.
3. Programming
STEP 1: ASYD - System Data 1, Index 77, bit 0: DAY/NIGHT mode Changeover via handset jack 0/1: Not
Required/Required.
STEP 2: ALDN - Assign LDN, allow night transfer, assign TYPE = 3, and the ADC number assigned in
ASPD.
STEP 3: ASPD - Assign abbreviated digit code (ADC) and access code to the dialed (000-999). This step is
required only if the access code and outside number are greater than eight digits.
STEP 4: ACFO - Assign call forwarding data, CF = 4: Night Connection, and the ADC assigned in ASPD.
STEP 5: ARRC - Allowing incoming route to out-going route. Use Alternative Route Index (ARI) D for
Direct Connection. Three possible restriction (RES) may be assigned; data “0” =
connection is restricted; data “1” = connection is allowed; or data “2” = toll restriction is
required. For NIGHT CONNECTION-OUTSIDE-SYSTEM, toll restriction is not
required.
STEP 6: ACFR - Assign Transfer Service Feature Index (TSFI) = 2: Direct In Termination Night Only, to be
allowed CCI: 1 (LDN). This allows LDN to go to Night transfer destination.